Invoicing for EU companies with 0% VAT || Delivery across Europe within 3 days ||  Contact  || Open MON - FRI: 09:00–16:00
Cart 0 €
Total price:
0 €
Number of products:
Checkout The cart is empty Goods in the cart
    • NEWS
    • SAFETY NOTICE: Recall of the ROCK EXOTICA OMNI 1.1 pulley manufactured between February 2020 and October 2022
    22.12.2022

    SAFETY NOTICE: Recall of the ROCK EXOTICA OMNI 1.1 pulley manufactured between February 2020 and October 2022

    SAFETY NOTICE: Recall of ROCK EXOTICA OMNI BLOCK 1.1 Pulley manufactured from February 2020 to October 2022

    The button assembly on a limited number of 1.1” Omni Swivels and related variants may not be secure.
    If the button is extended, the side plate may open and the rope may fall out, resulting in serious injury or death.
    It has been determined that a small number of pulleys manufactured from February 2020 to October 2022 may not have the appropriate
    thread locking agent or sealant that would allow the set screw to be pulled out. Under normal circumstances it is
    either a thread lock or sealant is sufficient to secure the button and prevent this problem.

    Rock Exotica is recalling Omni Block 1.1” pulleys manufactured between February 2020 and October 2022.
    These pulleys must be returned to the manufacturer for inspection/repair.

    Rock Exotica also issues an inspection notice for all Omni Block pulleys manufactured from 2018 to October 2022.
    The pulleys can be inspected by the user / competent person or if you are not comfortable with the inspection, you can return it directly to the manufacturer for inspection.
    Inspection criteria are detailed at the end of the document.

    All products should be inspected before and after each use.
    For Omni pulleys this inspection should include buttons and set screws along with checking for cracks / warping / corrosion, side plate action, pulleys
    and swivel eye, screws and overall condition.

    Accordingly, we are including additional information on checking the button set screws for earlier Omnis manufactured before 2018.

    Recall Notice for Omni 1.1” pulley variants, 20050xxx through 22304xxx: Discontinue use, retire and send to Rock Exotica.

    How to do it:
    a) Verify the Omni pulley model
    b) Find the serial number
    c) IF the serial number is in the range of 20050xxx to 22304xxx or is in the range of 20050xxx to 22304xxx it must be sent for inspection

    PULLEY IDENTIFICATION:

    SERIAL NUMBER IDENTIFICATION

    THE RECALL APPLIES TO PULLEYS MANUFACTURED FROM FEBRUARY 2020 TO OCTOBER 2022:
    FROM NUMBER 20050XXX TO 22304XXX

    FORM TO COMPLETE:
    https://forms.zohopublic.com/RockExotica/form/RockExoticaRecallSubmissionsde/formperma/zc-xmGz7qxW96l6hb9RYof_72oHs6nRX4c_jWiTiKA?zf_lang=en

    2018 to February 2020 Omni Pulley Inspection Notice:

    a) Identify the location of the screws on your Omni pulley.
    b) Compare the images in the inspection criteria with your pulley.
    c) Follow the inspection instructions to determine if you are required to return the pulleys for additional inspection by Rock Exotica

    SCREW LOCATION:

    FROM 2018 TO PRESENT (Serial number corresponding to this period starts with 18001xxx.)

    PRIOR TO 2018 (Serial number corresponding to this period includes all production dates 15365xxx or earlier.)

    OMNI-RIGGING BLOCK PULLEY INSPECTION SPECIFICATION MHP58

    If you judge that the screw according to the photos falls into the RETURN status, you must immediately stop using the defective product and send it to the manufacturer for inspection!

    Consent to the use of cookies

    This website uses cookies to provide services, personalize ads and analyze traffic. More information
    I agree to the use of all cookies.
    Reject, use only technical cookies.

    The item was added to the cart

    Related products

    Are you sure you want to empty the cart?